Researchers at Kanazawa University report in Applied Physics Letters the design of an ultrafast amplitude detector for use in high-speed atomic force microscopy.  The detector will enable the real-time recording of fast dynamical processes of biomolecules.

To improve our understanding of biomolecular processes happening within cells, techniques for visualizing and recording them are of key importance. High-speed atomic-force microscopy (HS-AFM) has become an important technique for the real-time observation of biological processes on the sub-molecular spatial scale and with sub-second time resolution. Still, a higher video frame rate is required for recording many important processes, such as ion transport motion or signaling mechanisms within membranes.  Now, Kenichi Umeda, Toshio Ando and Noriyuki Kodera from Kanazawa University and colleagues have designed an amplitude detector with ultrafast operation, the use of which in HS-AFM leads to a significantly improved temporal resolution.

The basic idea of AFM is to make a very small tip scan the surface of a sample. During this horizontal ('xy') scan, the tip, which is attached to a small cantilever, follows the sample's vertical ('z') profile, inducing a force on the cantilever that can be measured. The magnitude of the force at the 'xy' position can be related to the 'z' value; the 'xyz' data generated during a scan then result in a height map providing structural information about the investigated sample. In HS-AFM, the working principle is slightly more involved: the cantilever is made to oscillate near its resonance frequency. When the tip is moved around a surface, the variations in the amplitude of the cantilever's oscillation ” resulting from the tip's interaction with the sample's surface ” are recorded, as these provide a measure for the local 'z' value.  Amplitude variation detectors have an intrinsic slowness, called latency, as a finite time interval is normally required to detect a change in amplitude.  Amplitude detector latency is one of the main bottlenecks towards improving the speed of HS-AFM.

Umeda and colleagues invented a cleverly designed amplitude detector that has zero intrinsic latency.  The detector is based on the trigonometric calculation, in which the calculation of A2 = A2(sin2‰ct + cos2‰ct) = (Asin‰ct)2 + (Acos‰ct)2 is performed using an incoming sin wave Asin‰ct.  The key step for the fast detection was to obtain the cosine wave Acos‰ct by the differential operation. Hence, the electronic circuit invented here was named DB (differential based) amplitude detector.  The scientists built a test circuit with this architecture, and evaluated its speed performance in the range of 300 “ 1500 kHz carrier frequency.  The DB amplitude detector resulted in about 10 times faster characteristics than the schemes typically used until now.

The researchers also tested the DB amplitude detector in a real HS-AFM experiment.  They successfully recorded actin filaments, one of the cytoskeletal filaments found in eukaryotic cells, with a scanning velocity of 800 micrometers per second, which is four times faster than with a typical setup.  The higher recording speeds not only results in a higher video frame rate (50 milliseconds per frame) but it also has the advantage of being less invasive ” in the standard setup, the filament collapsed after 1 second, whereas with the new detector, the biomolecule was stably observed for 30 seconds.

The detector of Umeda and colleagues promises better performance in terms of imaging speed and less-invasiveness compared to conventional detectors.  Quoting the scientists: "By overcoming the obstacle of the amplitude detector bandwidth, we have opened the road to increasing the temporal resolution of HS-AFM."
Source: https://www.prnewswire.com/news-releases/kanazawa-university-research-speeding-up-atomic-force-microscopy-301429726.html

Tags:

Kanazawa, University, AFM, Amplitude, Detector Low Cost Press Release Distribution Websites, Cheap Press Release Distribution Services, Affordable Press Release Distribution Site, Free Press Release Distribution Website, Free Press Release Distribution Services

Company Information

Company Name Contact Person Contact Number Email Id Website Address
Kering +33 (0)1 45 64 61 00 actionnaire@kering.com http://www.kering.com/

Other Research Related Press Release News

Flat Glass Market Report, Share, Size, Trends, Growth, Demand by Region and Forecast Till 2024 Free

According to the latest report by IMARC Group, titled “Flat Glass Market: Global Industry Trends, Share, Size, Growth, Opportunity and Forecast 20...Read More


Hydroxychloroquine Market Size, By Disease Indication, Distribution Channel, Share, Regional Analysis and Forecast to 2026 Free

Hydroxychloroquine Market report covers the COVID-19 impact analysis giving a detailed statistics of market share, size along with regional and ...Read More


Medical Alert Systems Market Report 2020, COVID-19 Impact, Market Trends, Share, Size and Forecast Till 2026 Free

The research report on the global Medical Alert Systems Market offers an all-encompassing analysis of recent and upcoming states of this industry whic...Read More


Dicyandiamide Market Growth Powered With Latest Development Scenario and Influencing Trends and Forecast 2027 Free

Global Dicyandiamide Market outlook to 2027 is a focused and extensive research of the Dicyandiamide industry with a focus on the world market trend. ...Read More


Global Suspension Spring Market 2020 with Covid-19 Effect Analysis, Growth Opportunities, Top Key Players and Emerging Opportunities with Current Trends Analysis 2024 Free

The Suspension Spring Market report, added by Global Marketers, descriptively covers the present & future growth trends, in addition to highlighti...Read More